"Значимость человека определяется не тем, чего он достиг, а скорее тем, чего он дерзает достигнуть." Кахлиль Гибран |
A system for measuring electric resistivity of thin ribbons as function of the temperature was built.
Electric resistivity of Fe-based and Co-based ribbons are close one to other. At the same time the electric resistivity of Al-based ribbon three times less of both of them. Such designation explains by difference in ribbons compositions.
Temperature resistance coefficient of amorphous ribbons essentially less of crystalline. For the all types of ribbons temperature resistance coefficient constant in the temperature range till 150 -200 C?.
Electric resistivity of amorphous ribbons essentially drops at crystallization temperature. Such fact explains by difference in amorphous and crystalline structure of ribbons.
The precision of resistivity measuring strongly depends on precision of ribbon thickness measuring.
4. Electricity. Part A. Technology School of the Open University, Tel Aviv,1991. 5. P. Sears, M. Zimansky. High School Physics, Electricity and Magnetism,1996.
|